Rev. 06Dec2006SPECIAL NOTE: For accurate test results, the IEC 60286-16 standard needs to be observedunder all conditions and circumstances. GETTING S
Line #519 April 13:27 hours-Date and time stampLine #6Single Test Result - single test only, no averaging of multiple tests OR (if multiple tests ta
--VIEW JOB FILE using "Word Mobile"--All Ivie STI-PA Job Files are saved using their "Job Name" in a standard text format with a &
3. Now that "Word Mobile" is running you will see a list of files. Tap on the desired file to openit. That's all there is to it.4. To
--HOW TO REGISTER--The Ivie STI-PA software runs in Unregistered/Demonstration mode until the software isregistered. There is a fee for registration.F
--STI-PA Test Signal--The user needs to provide a playback device for the Ivie STI-PA test signal. The Ivie STI-PAtest signal is on the CD supplied w
Step 9 - NOW BEFORE WE FORGET we need to set the input selection back to themicrophone. Let's do that now. Press the "Options" menu a
in the room so that the SPL meter indicates the Target SPL for this room.(or is at least within thetarget level brackets)Step 9 - OCTAVE LEVELS: An e
---Saving the JOB FILE---You do not have to save the Job File because it is always being saved after each data entry. While viewing the Job File you c
--AVERAGING--The IEC Standard 60268-16 (2003-05)states the following: "The measurements should be repeated several times and the results averaged
--CALIBRATION--All instruments require calibration and the Sound Pressure Level Meter in the Ivie STI-PAprogram is no exception.If you purchased the I
6a. Tap and drag in the "Calibrator SPL:" window to completely hi-lite the "94.0"6b. Use the keyboard to enter the calibration con
--HOW FILES ARE MANAGED--When the Ivie STI-PA program is launched, it loads the name of the last used Job File into theprogram. The name of the Job f
--OPENING A "NEW JOB"--1. Press the "File" menu and select "New Job.."2.In the Name: window overwrite the "New Job&
--VIEW JOB FILES--You can easily review any or all of the measurements that you have "Saved." To view thecurrently opened Job File, Press th
Comments to this Manuals